ST124 AIM-TTI Aim-TTi ST124 RF Power Meter 12.4GHz USB 2.0

Part Nnumber
ST124
Description
Aim-TTi ST124 RF Power Meter 12.4GHz USB 2.0
Producer
AIM-TTI
Basic price
1257,92 EUR

The product with part number ST124 (Aim-TTi ST124 RF Power Meter 12.4GHz USB 2.0) is from company AIM-TTI and distributed with basic unit price 1257,92 EUR. Minimal order quantity is 1 pc.


ConnectivityUSB 2.0 Connector TypeSMA Dimensions125 x 43 x 34mm Height34mm Length125mm Maximum Frequency12.4GHz Maximum Linearity Error±1.46dB Maximum Measurement Speed50sps Maximum Operating Temperature+50°C Maximum Power Measurement+20dBm Minimum Frequency10 MHz Minimum Operating Temperature0°C Weight83g Width43mm Product Details TTi Microwave Power Meters TTi-Satori ST series power sensors are complete miniature RF & Microwave power meters. They contain a CPU which controls the sensor, processes the measurement results and operates the interface. All measurement data and settings are transmitted to and from a PC via a USB interface. The virtual power meter software for Windows (supplied) creates a classic microwave power meter. Replacement solution for conventional power meter and sensor combinationSimple USB connection to laptop or PC (connectivity USB 2.0, cable length up to 5m)USB power supply current approximately 50mAAble to have multiple sensor heads connected to one laptop or PC and operated simultaneouslySensor cable length (standard) 193cmNo reference calibrator requiredLightweight (83 grams) and easy to useRobust construction with excellent reliabilityConvenient for production test and field serviceDimensions (max) 34H x 43W x 125L mm   ST124 ST265 Frequency 10MHz → 12.4GHz 10 MHz → 26.5 GHz Measurement -50 → +20dBm CW -50 → +20dBm CW Operating Temperature 0 → 50 deg C 0 → 50 deg C Shock 25G, 11 ms 25G, 11 ms Vibration 15G, 100 → 2000Hz 15G, 100 → 2000Hz Linearity error 25 +/- 5 deg C +/-0.26 dB; -40dBm → +10dBm; 50MHz ≤ f ≤ 12.4GHz+/-0.46 dB; +10dBm → +20dBm; 50MHz ≤ f ≤ 12.4GHz+/-0.43 dB; -40dBm → +10dBm; f ±0.27 dB; -35dBm → +20dBm; 10 MHz → 26.5 GHz Linearity variation 25 +/- 25 deg C +/-0.5 dB; 50MHz ≤ f ≤ 12.4GHz +/-0.7 dB; 10 MHz ≤ f ±0.2 dB; 10 MHz → 6 GHz; -35dBm to +20dBm±0.25 dB; 6 GHz → 18.5 GHz; -35dBm → +20 dBm±0.46 dB; 18.5 GHz → 26.5 GHz; -35 dBm → +20 dBm Cal factor error 25 +/- 5 deg C +/-0.17 dB; 10 MHz ±0.16 dB; 10 MHz → 6 GHz±0.19 dB; 6 GHz → 18.5 GHz±0.21 dB; 18.5GHz → 26.5 GHz Cal factor variation 25 +/- 5 deg C ±0.45 dB; f ≥ 50MHz ±0.67dB; f ±0.2 dB; 10 MHz → 6 GHz±0.3 dB; 6 GHz → 18.5 GHz±0.35 dB; 18.5 GHz → 26.5 GHz Zero set +/-1.8 nW ±1.6 nW Noise 0.15 nW RMS 0.14nW standard deviation Input SWR - max 1.2:1 1.25:1 10 MHz → 18 GHz1.35:1 18 GHz → 26.5GHz Measurement Speed-50 to -35 dBm-35 to -20 dBm-20 to +20 dBm 8 measurements per sec33 measurements per sec.50 measurements per sec. 8 measurements per sec33 measurements per sec.50 measurements per sec. Max input power (damage level) 200mW CW (+23dBm) 200mW CW (+23dBm) Connector type SMA (m) K type* (m) *K Connector is a registered trademark of the Anritsu Company. Microwave Power Meters


Following Parts

Random Products

(keyword ST124 AIM-TTI Aim-TTi ST124 RF Power Meter 12.4GHz USB 2.0)
© 2015 Industry Server